The full name of S. L. type cable is __________.

This question was previously asked in
MPPGCL JE Electrical 28 April 2023 Shift 2 Official Paper
View all MPPGCL Junior Engineer Papers >
  1. straight line type cable
  2. stranded line type cable
  3. separate lead type cable
  4. selective level type cable

Answer (Detailed Solution Below)

Option 3 : separate lead type cable
Free
MPPGCL JE Electrical Full Test 1
100 Qs. 100 Marks 120 Mins

Detailed Solution

Download Solution PDF

Classification of cable based on construction

Belted cable:

  • In such cables, the conductors (usually three) are bunched together and then bound with an insulating paper ‘belt’.
  • In such cables, each conductor is insulated using paper impregnated with a suitable dielectric. The gaps between the conductors and the insulating paper belt are filled with a fibrous dielectric material such as Jute or Hessian. 
  • There are some limitations of such construction. Since the electric field is tangential, the insulation provided is stressed. As a result, the dielectric strength falls over time. Hence, such construction isn’t preferred for voltage levels above 11 kV.


Screened cable:

It is further divided as H type and S.L. type cables:

H-Type Cable:

  • H-type cables are high-voltage paper-insulated cables designed for underground power transmission. They are mainly used for voltages up to 66 kV.
  • The three cores are individually insulated with paper and then covered by a metallic screen/cover. These metallic covers are perforated. As a result, such construction allows the three metallic screens to touch each other.


S. L. Type Cable:

  • The full form of SL-type cable is Separate Lead type cable. Such construction is limited for voltages up to 66kV only.
  • SL-type cables are an improved version of H-type cables, used for underground high-voltage power transmission. They feature separate lead sheaths over each core, providing better insulation and fault protection compared to H-type cables.


Pressure cables:

  • For voltages beyond 66 kV, the electrostatic stresses in the cables exceed the acceptable values and solid cables become unreliable.
  • This occurs mainly because voids are created when voltages exceed 66 kV. Hence, instead of solid cables, we use Pressure cables.
  • Typically, such cables are either oil filled or gas filled.

Latest MPPGCL Junior Engineer Updates

Last updated on May 29, 2025

-> MPPGCL Junior Engineer result PDF has been released at the offiical website.

-> The MPPGCL Junior Engineer Exam Date has been announced.

-> The MPPGCL Junior Engineer Notification was released for 284 vacancies.

-> Candidates can apply online from 23rd December 2024 to 24th January 2025.

-> The selection process includes a Computer Based Test and Document Verification.

-> Candidates can check the MPPGCL JE Previous Year Papers which helps to understand the difficulty level of the exam.

Hot Links: teen patti rummy 51 bonus teen patti 500 bonus teen patti master king teen patti