The voltages that appears across the breaking contact at the instant of arc extinction is called_______ 

This question was previously asked in
PGCIL NER DT (Electrical) 27 Feb 2022 Official Paper
View all PGCIL Diploma Trainee Papers >
  1. Restriking Voltage 
  2. Recovery Voltage 
  3. Active Recovery Voltage 
  4. Arc Voltage 

Answer (Detailed Solution Below)

Option 1 : Restriking Voltage 
Free
PGCI DT EE Power System Mock Test
20 Qs. 20 Marks 15 Mins

Detailed Solution

Download Solution PDF

Restriking voltage is the transient voltage that appears across the contacts of a circuit breaker at the instant the arc is extinguished. This voltage can cause the arc to restrike if the insulation strength across the contacts is not sufficient. It plays a crucial role in the interruption process and is usually damped out after a few oscillations, giving way to the steady-state recovery voltage.

Concept

The following are the important terms used in the circuit breaker analysis:

1.) Arc Voltage

  • Arc voltage is the voltage that is responsible for maintaining the arc between the contacts of the circuit breaker.
  • At the time of the circuit breaker contacts opening, an arc is struck between the contacts due to the ionization of the medium surrounding the contacts.
  • A small potential difference exists between the contacts and it is responsible for maintaining the arc. This voltage is called the Arc Voltage.
     

2.) Restriking Voltage

  • Whenever arc interruption occurs at zero current instant, the voltage across the circuit breaker gap will suddenly rise from zero to a very high value. This high voltage will be transient in nature.
  • It is the transient voltage that appears across the contacts at or near current zero during the arcing period.
     

3.) Recovery Voltage

  • ​It is defined as the voltage appearing across the circuit breaker contacts after the final arc extinction and after all the transients die out (or disappear). 
     

4.) Active Recovery Voltage

  • Active Recovery Voltage refers to the voltage that reappears across the contacts of a circuit breaker after the arc between the contacts is extinguished. It represents the system voltage that stabilizes across the open contacts once the transient effects subside.

  • This voltage can influence the breaker’s ability to prevent re-ignition of the arc and ensures the system remains stable after interruption.

  • It's distinct from restriking voltage, which is the transient voltage that appears immediately after arc extinction and may cause re-ignition.

 

Latest PGCIL Diploma Trainee Updates

Last updated on May 9, 2025

-> PGCIL Diploma Trainee result 2025 will be released in the third week of May. 

-> The PGCIL Diploma Trainee Answer key 2025 has been released on 12th April. Candidates can raise objection from 12 April to 14 April 2025.

-> The PGCIL DT Exam was conducted on 11 April 2025. 

-> Candidates had applied online from 21st October 2024 to 19th November 2024.

-> A total of 666 vacancies have been released.

-> Candidates between 18 -27 years of age, with a diploma in the concerned stream are eligible.

-> Attempt PGCIL Diploma Trainee Previous Year Papers for good preparation.

Hot Links: teen patti neta yono teen patti teen patti bonus