What is the effective length of the column when effectively restrained against translation at both the ends but restrained against rotation at one end only?

This question was previously asked in
BPSC AE Paper 5 (Civil) 11 Nov 2022 Official Paper
View all BPSC AE Papers >
  1. 0.81 L
  2. 0.65 L
  3. 0.5 L
  4. 0.707 L

Answer (Detailed Solution Below)

Option 1 : 0.81 L
Free
BPSC AE General Studies Mock Test
20 Qs. 40 Marks 25 Mins

Detailed Solution

Download Solution PDF

Explanation:

As per IS: 800 – 2007

For column, effectively restrained against translation at both the ends but restrained against rotation at one end only

Effective length is 0.8L

Design value of effective length factor for various combination are given below:

Latest BPSC AE Updates

Last updated on Jun 13, 2025

-> BPSC AE 2025 exam date has been revised. The exam will be conducted on July 17, 18 & 19 now. 

-> Candidates who were facing technical issues while filling form can now fill the BPSC AE application form 2025 without any issue. 

->BPSC AE age limit 2025 has been revised.

->BPSC AE application form 2025  was released on April 30. The last date to fill BPSC AE form 2025 was May 28. 

->BPSC AE interview call letters released for Advt. 32/2024.

->BPSC AE notification 2025 has been released. 

->A total of 1024 vacancies are announced through BPSC AE recruitment 2025

->The BPSC Exam Calendar 2025 has been released for the Assistant Engineer Recruitment.

-> The selection will be based on a written exam and evaluation of work experience.

-> Candidates with a graduation in the concerned engineering stream are eligible for this post.

-> To prepare for the exam solve BPSC AE Previous Year Papers. Also, attempt the BPSC AE Civil  Mock Tests.

Hot Links: teen patti stars teen patti lucky teen patti flush teen patti gold new version 2024 teen patti list