A 250 V moving iron voltmeter takes a current of 0.05 A when connected to a 250 V DC supply. The coil has an inductance of 1 H. What will be the reading on the meter when connected to a 250 V, 100 Hz supply? Assume impedance at 100 Hz to be 6000 Ω.

This question was previously asked in
MPPGCL JE Electrical 19 March 2019 Shift 2 Official Paper
View all MPPGCL Junior Engineer Papers >
  1. 248 V
  2. 208.33 V
  3. 280.33 V
  4. 284 V

Answer (Detailed Solution Below)

Option 2 : 208.33 V
Free
MPPGCL JE Electrical Full Test 1
100 Qs. 100 Marks 120 Mins

Detailed Solution

Download Solution PDF

Concept

The voltage reading of a moving iron voltmeter corresponds to the true RMS voltage across its resistance:

Vmeter = IAC × R

where, IAC = AC current

R = DC resistance

Calculation

Given, VDC = 250 V

IDC = 0.05 A

L = 1 H

f = 100 Hz

Impedance at 100Hz, ZAC = 6000 Ω

ZAC = 5040 Ω 

Vmeter = (0.04167× (5000)

Vmeter = 208.33 V