For a 3-phase semi converter, if the firing angle for the thyristor is 90°, the free-wheeling diode will conduct for a period of ______,

This question was previously asked in
HPCL Engineer Electrical 11 Aug 2021 Official Paper
View all HPCL Engineer Papers >
  1. 90°
  2. 30°
  3. 120°

Answer (Detailed Solution Below)

Option 2 : 30°
Free
Environmental Engineering for All AE/JE Civil Exams Mock Test
10.4 K Users
20 Questions 20 Marks 20 Mins

Detailed Solution

Download Solution PDF

Concept:

  • A 3ϕ semi converter works in a continuous mode of operation for α ≤ 60°
  • In a continuous mode of operation, the free-wheeling diode does not conduct.
  • For α > 60°, the mode of operation becomes discontinuous in nature.
  • In a discontinuous mode of operation, the free-wheeling diode conducts for α - 60°.

​Calculation:

Given, α = 90° 

Conduction period of free-wheeling diode = 90° - 60° 

Conduction period of free-wheeling diode = 30° 

Latest HPCL Engineer Updates

Last updated on Jun 2, 2025

-> HPCL Engineer 2025 notification has been released on June 1, 2025.

-> A total of 175 vacancies have been announced for the HPCL Engineer post in Civil, Electrical, Mechanical, Chemical engineering.

-> HPCL Engineer Online application will be activated from 1st June 2025 to 30th June 2025.

-> Candidates with a full-time engineering discipline in the relevant stream are eligible to apply.

-> The selection will be based on a Computer Based Test Group Task and/or Interview. Prepare for the exam using HPCL Engineer Previous Year Papers.

More Three Phase Thyristor Converter Circuits Questions

Get Free Access Now
Hot Links: teen patti 500 bonus teen patti game - 3patti poker teen patti master 51 bonus teen patti lucky all teen patti game